go home
COMPANY PRODUCTS PROJECT SERVICES EQUIPMENT CONTACT US
Brass
Copper
Copper Tubes
Air Conditioning Tubes
LWC & PCC
Pre-lagged Copper Tubes
Insulated Tubes
Hexagonal / Octagonal Tubes
Square / Rectangular Tubes
Finned Tubes
Copper-Alloy Tubes
Sheet / Plate
Round Bar / Square Bar / Flat Bar
Stainless Steel
Carbon Steel
Aluminum
Specialty Metals
Gilsonite
AS 1571 Straight
Australian Standard AS 1571 Straight Tubes
Outside Diameter Wall Thickness Form Temper High Pressure Compatible
inches mm mm
1/4" 6.35 0.81 6m Straight Hard Drawn R410A
3/8" 9.52 0.81 6m Straight Bendable R410A
1/2" 12.70 0.81 6m Straight Bendable R410A
5/8" 15.88 0.81 6m Straight Bendable  
5/8" 15.88 1.02 6m Straight Bendable R410A
3/4" 19.05 0.91 6m Straight Bendable  
3/4" 19.05 1.02 6m Straight Bendable  
3/4" 19.05 1.14 6m Straight Bendable R410A
7/8" 22.23 0.91 6m Straight Bendable  
7/8" 22.23 1.40 6m Straight Hard Drawn R410A
1" 25.40 0.91 6m Straight Hard Drawn  
1" 25.40 1.63 6m Straight Hard Drawn R410A
1-1/8" 28.58 0.91 6m Straight Hard Drawn  
1-1/8" 28.58 1.22 6m Straight Hard Drawn  
1-1/8" 28.58 1.83 6m Straight Hard Drawn R410A
1-1/4" 31.75 0.91 6m Straight Hard Drawn  
1-1/4" 31.75 1.22 6m Straight Hard Drawn  
1-1/4" 31.75 2.03 6m Straight Hard Drawn R410A
1-3/8" 34.90 0.91 6m Straight Hard Drawn  
1-3/8" 34.90 1.22 6m Straight Hard Drawn  
1-3/8" 34.90 2.03 6m Straight Hard Drawn R410A
1-1/2" 38.10 0.91 6m Straight Hard Drawn  
1-1/2" 38.10 1.22 6m Straight Hard Drawn  
1-1/2" 38.10 2.29 6m Straight Hard Drawn R410A
1-5/8" 41.28 0.91 6m Straight Hard Drawn  
1-5/8" 41.28 1.22 6m Straight Hard Drawn  
1-5/8" 41.28 2.41 6m Straight Hard Drawn R410A
2" 50.80 1.22 6m Straight Hard Drawn  
2-1/8" 54.00 0.91 6m Straight Hard Drawn  
2-1/8" 54.00 1.22 6m Straight Hard Drawn  
2-5/8" 66.70 1.22 6m Straight Hard Drawn  
3" 76.20 1.63 6m Straight Hard Drawn  
4" 101.60 1.63 6m Straight Hard Drawn  
*** R401 A copper tube is designed to comply with AS4041
*** R401 A copper tube is capable of withstanding working pressure of 4131 kPa at a temperature of 65℃.
AS 1571 Coil
AS 1571 ANNEALED COILS
Outside Diameter Wall Thickness Form Temper High Pressure Compatible
inches mm mm
1/4" 6.35 0.56 30m Coil Annealed  
1/4" 6.35 0.71 30m Coil Annealed  
1/4" 6.35 0.81 30m Coil Annealed R410A
1/4" 6.35 0.91 30m Coil Annealed R410A
1/4" 6.35 1.22 30m Coil Annealed  
5/16" 7.94 0.56 30m Coil Annealed  
5/16" 7.94 0.71 30m Coil Annealed  
5/16" 7.94 0.81 30m Coil Annealed R410A
5/16" 7.94 0.91 30m Coil Annealed R410A
3/8" 9.52 0.56 30m Coil Annealed  
3/8" 9.52 0.71 30m Coil Annealed  
3/8" 9.52 0.81 30m Coil Annealed R410A
3/8" 9.52 0.91 30m Coil Annealed R410A
1/2" 12.70 0.56 30m Coil Annealed  
1/2" 12.70 0.71 30m Coil Annealed  
1/2" 12.70 0.81 30m Coil Annealed R410A
1/2" 12.70 0.91 30m Coil Annealed R410A
5/8" 15.88 0.56 30m Coil Annealed  
5/8" 15.88 0.71 30m Coil Annealed  
5/8" 15.88 0.81 30m Coil Annealed  
5/8" 15.88 0.91 30m Coil Annealed  
5/8" 15.88 1.02 30m Coil Annealed R410A
3/4" 19.05 0.71 30m Coil Annealed  
3/4" 19.05 0.91 30m Coil Annealed  
3/4" 19.05 1.22 30m Coil Annealed R410A
7/8" 22.23 0.91 30m Coil Annealed  
*** R401 A copper tube is designed to comply with AS4041
*** R401 A copper tube is capable of withstanding working pressure of 4131 kPa at a temperature of 65℃.
ASTM B280 Straight
ASTM B280 STRAIGHT LENGTH
Standard Size, In. Outside Diameter in. (mm) Wall Thickness in. (mm) Weight lb/ft (kg/m) ToleranceB
AverageA Outside Diameter +/-, in. (mm) Wall Thickness +/-, in. (mm)
3/8 0.375 (9.52) 0.030 (0.762) 0.126 (0.187) 0.001 (0.025) 0.003 (0.08)
1/2 0.500 (12.70) 0.035 (0.889) 0.198 (0.295) 0.001 (0.025) 0.004 (0.10)
5/8 0.625 (15.90) 0.040 (1.020) 0.285 (0.424) 0.001 (0.025) 0.004 (0.10)
3/4 0.750 (19.10) 0.042 (1.070) 0.362 (0.539) 0.001 (0.025) 0.004 (0.10)
7/8 0.875 (22.20) 0.045 (1.140) 0.455 (0.677) 0.001 (0.025) 0.004 (0.10)
1 1/8 1.125 (28.60) 0.050 (1.270) 0.655 (0.975) 0.0015 (0.038) 0.005 (0.13)
1 3/8 1.375 (34.90) 0.055 (1.400) 0.884 (1.32) 0.0015 (0.038) 0.006 (0.15)
1 5/8 1.625 (41.30) 0.060 (1.520) 1.14 (1.70) 0.002 (0.051) 0.006 (0.15)
2 1/8 2.125 (54.00) 0.070 (1.780) 1.75 (2.60) 0.002 (0.051) 0.007 (0.18)
2 5/8 2.625 (66.70) 0.080 (2.030) 2.48 (3.69) 0.002 (0.051) 0.008 (0.20)
3 1/8 3.125 (79.40) 0.090 (2.290) 3.33 (4.96) 0.002 (0.051) 0.009 (0.23)
3 5/8 3.625 (92.10) 0.100 (2.540) 4.29 (6.38) 0.002 (0.051) 0.010 (0.25)
4 1/8 4.125 (105.00) 0.110 (2.790) 5.38 (8.01) 0.002 (0.051) 0.011 (0.28)
Note : Applicable to drawn temper tube only

A The average outside diametr of a tube is the average of the maximum and minimum outside diameters as
B The tolerances listed represent the maximum deviation at any point
ASTM B280 Coil
ASTM B280 COIL LENGTH
Standard Size, In. Outside Diameter in. (mm) Wall Thickness in. (mm) Weight lb/ft (kg/m) ToleranceB
AverageA Outside Diameter +/-, in. (mm) Wall Thickness +/-, in. (mm)
1/8 0.125 (3.18) 0.030 (0.762) 0.0347 (0.0516) 0.002 (0.051) 0.003 (0.08)
3/16 0.187 (4.75) 0.030 (0.762) 0.0575 (0.0856) 0.002 (0.051) 0.003 (0.08)
1/4 0.250 (6.35) 0.030 (0.762) 0.0804 (0.120) 0.002 (0.051) 0.003 (0.08)
5/16 0.312 (7.92) 0.032 (0.813) 0.109 (0.162) 0.002 (0.051) 0.003 (0.08)
3/8 0.375 (9.52) 0.032 (0.813) 0.134 (0.199) 0.002 (0.051) 0.003 (0.08)
1/2 0.500 (12.70) 0.032 (0.813) 0.182 (0.271) 0.002 (0.051) 0.003 (0.08)
5/8 0.625 (15.90) 0.035 (0.889) 0.251 (0.373) 0.002 (0.051) 0.004 (0.10)
3/4 0.750 (19.10) 0.035 (0.889) 0.305 (0.454) 0.0025 (0.064) 0.004 (0.10)
3/4 0.750 (19.10 0.042 (1.070) 0.362 (0.539) 0.0025 (0.064) 0.004 (0.10)
7/8 0.875 (22.20) 0.045 (1.140) 0.455 (0.677) 0.003 (0.076) 0.004 (0.10)
1-1/8 1.125 (28.60) 0.050 (1.270) 0.665 (0.975) 0.0035 (0.089) 0.005 (0.13)
1-3/8 1.375 (34.90) 0.055 (1.40) 0.884 (1.32) 0.004 (0.10) 0.006 (0.15)
1-5/8 1.625 (41.30) 0.060 (1.520) 1.14 (1.70) 0.0045 (0.11) 0.006 (0.15)
A The average outside diametr of a tube is the average of the maximum and minimum outside diameters as
B The tolerances listed represent the maximum deviation at any point
HOW